All Categories >

Product

+
  • df9e247a-f4d3-46db-bff5-50387fe98f23.png

Quantum and interband cascade lasers

DFB QCLs and ICLs with semiconductor cooling in HHL packaging Center wavelength range: 3.00 – 11.00 μm (3333–1–909 cm⁻¹) Output power up to 150 mW, depending on the specific model Wavelength, package type, and output power can be customized to meet specific requirements.

Classification:

Detail

Parameters

Technical Data

Characteristics

● Single-frequency distributed-feedback quantum cascade lasers and interband cascade lasers (DFB QCLs and ICLs)

● High-Heat-Load (HHL) packaging simplifies thermal management and system integration.

● The collimated laser beam exits through a wedge-shaped window.

● Used in chemical analysis, sensing, and infrared countermeasures technology

● Customizable package types and wavelengths (3–12 μm); please contact us. Technical Sales

The mid-infrared quantum cascade lasers sold on this page feature a high‑thermal‑load (HHL) package, industry‑standard pinout, and package dimensions. Each package includes an integrated thermistor and a thermoelectric cooler (TEC) for active temperature control, extending the laser’s operational life, as well as a built-in aspheric lens to collimate the laser’s output beam.

Distributed-feedback QCLs and ICLs emit at well-defined wavelengths and are widely used in applications such as chemical sensing and sample analysis. They operate in single longitudinal and single transverse modes. By adjusting the drive current and operating temperature, the laser’s output frequency can be tuned within a narrow range of at least 1 cm⁻¹. Prior to shipment, each laser is tested at an automated station that measures its output spectrum, output power, and L‑I‑V characteristics. The results of these measurements are shown below, and a data sheet is included with every laser.

Our ICL emits a horizontally polarized beam with a wavelength of 4.0 μm, whereas the QCL emits a vertically polarized beam at 11 μm. ICLs typically also feature lower voltage requirements and threshold currents, resulting in lower optical output power. In contrast, QCLs consume more power and deliver higher output power.

Some of Chongfan Technology’s high‑thermal‑load DFB quantum cascade lasers and interband cascade lasers are particularly well suited for gas sensing and analysis. The emission wavelengths of certain high‑thermal‑load quantum cascade lasers are ideally matched to many of the gases commonly studied in spectroscopy. These DFB quantum cascade lasers are guaranteed to reach the specified wavelength within their tuning range and operate at a single frequency, enabling wavelength tuning to target specific gas absorption lines. For a list of these QCLs and ICLs, please refer to the Spectra tab above; for more information, click the info icon () below to view the corresponding tab.

Package Details
The beam exit height, measured from the bottom of the package, is 12.7 ± 0.13 mm. An anti‑reflection‑coated black‑diamond aspheric lens collimates the output beam, which then exits the package through a wedged zinc selenide (ZnS) window. The wedged window not only suppresses back‑reflections from the laser chip’s rear facet but also introduces a downward angular offset of 2.0° ± 1.5° or 2.0° ± 0.75° relative to the nominal direction. All lasers in our inventory are hermetically sealed, though not fully airtight; fully sealed versions are also available—please contact us for further details. Technical Sales 。

Each laser is electrically isolated from its mounting base. These lasers have a maximum thermal load of 38 W, so they must be mounted on a thermally conductive surface to prevent heat buildup. Chongfan Technology’s… LCM100 ( /M ) Liquid-cooled mounts provide additional thermal management for lasers packaged in HHL packages. CAB4007A and CAB4007B The LD/TEC connection wires are used to connect, respectively. ITC5225 or ITC4005QCL The controller can be mounted on the LCM100(/M) mounting base or connected directly to an HHL‑packaged laser. Please note that third‑party cables designed for high‑thermal‑load packages typically do not support the internal semiconductor cooler’s maximum current of 4.5 A. Additional operating instructions are provided on the label. These QCLs and ICLs are intended specifically for continuous‑wave operation. While pulsed operation is possible, it imposes limitations on current regulation and does not guarantee optimal performance. Furthermore, these lasers lack built-in photodiodes for monitoring, so they cannot operate in constant‑power mode.

Chongfan Technology has also specially designed compact models for OEM applications. D-mount package a quantum cascade laser (12.0 mm × 4.5 mm × 2.8 mm).

Distributed-feedback interband-cascade laser, with a center wavelength of 3.00–4.00 μm, in a horizontal HHL package.

 

Distributed-feedback quantum cascade laser, center wavelength 4.00–5.00 μm, housed in a horizontal HHL package.

 

Distributed-feedback quantum cascade laser, center wavelength 5.00–6.00 μm, housed in a horizontal HHL package.

 

Distributed-feedback quantum cascade laser, center wavelength 6.00–7.00 μm, housed in a horizontal HHL package.

 

Distributed-feedback quantum cascade laser, center wavelength 7.00–8.00 μm, housed in a horizontal HHL package.

 

Distributed-feedback quantum cascade laser, center wavelength 8.00–9.00 μm, housed in a horizontal HHL package.

 

Distributed-feedback quantum cascade laser, center wavelength 9.00–10.00 μm, housed in a horizontal HHL package.

 

Distributed-feedback quantum cascade laser, center wavelength 10.00–11.00 μm, housed in a horizontal HHL package.

Gas-phase spectroscopy using distributed-feedback lasers

Distributed-feedback quantum cascade lasers and interband cascade lasers (DFB QCLs and ICLs) offer numerous advantages well suited to spectroscopic applications. First, they emit at a single wavelength in the mid-infrared region, which coincides with the absorption bands of many gaseous species. Moreover, their emission wavelength can be readily tuned by adjusting the drive current and operating temperature—typically spanning 1–5 cm⁻¹—making them ideal for resolving narrow gas‑absorption lines. Finally, quantum cascade lasers deliver relatively high output powers (usually 40–120 mW at threshold), thereby enhancing measurement sensitivity. Interband cascade lasers generally exhibit lower output powers but much lower power consumption.

The emission wavelength range of the DFB QCLs on this page spans from 4.00 to 11.00 μm (2500 cm⁻¹ to 909 cm⁻¹), while that of the DFB ICLs ranges from 3.00 to 4.00 μm (3333 cm⁻¹ to 2500 cm⁻¹). If the wavelengths required for your application are not available among our standard stock products, please contact us. Technical Sales Custom wavelength.

The tuning range of DFB QCLs and ICLs depends largely on the specific laser being used. Each DFB QCL or ICL is unique, with its own threshold current, turnover current, and spectral characteristics. Because the wavelength and output power of DFB QCLs and ICLs vary across their tuning ranges, it is not always optimal to operate the laser near the turnover current when performing spectroscopic measurements that require a specific wavelength. The drive current and operating temperature of DFB QCLs and ICLs can be adjusted to shift the output signal to the desired wavelength and power level.

An example of the absorption spectrum of nitric oxide (NO) is shown in Figure 5.2. The blue‑shaded region centered at 1900 cm⁻¹ overlaps with the tuning range of the QD5263HH QCL; the tuning characteristics of the QD5263HH QCL are presented in Figure 5.3 for comparison. The QD5263HH QCL can be precisely tuned to the NO absorption peak at 1900 cm⁻¹.

DFB QCLs and ICLs are ideally suited for photoacoustic spectroscopy, a technique that leverages the photoacoustic effect to accurately measure trace gas concentrations across a wide range of applications. Chongfan Technology offers… Photoacoustic Detection Module , which can be used in conjunction with our DFB QCLs and ICLs to build custom QEPAS sensors tailored for specific gases. We also offer solutions optimized for methane absorption lines. Quartz-Enhanced Photoacoustic Detection System , used for detecting trace amounts of methane in gases.

Figure 5.2: The shaded region overlaps with the tuning range of the QD5263HH distributed-feedback QCL. Tuning data for the QD5263HH QCL example can be found in Figure 5.3.
Figure 5.3 Tuning data for an example of a QD5263HH distributed-feedback QCL. As shown in Figure 5.2, this laser can be used to detect the absorption peak of nitric oxide (NO).
Quantum and interband cascade lasers

Other Products

I want to consult

Submission