Light | Time-of-flight-resolved stimulated Raman microscopy based on ultra-low Bessel photobombs
Author:
Reading Guidance
Recently, Department of Biomedical Engineering, National University of SingaporeProfessor Wong Chi-waiThe leading biomedical optical imaging team has successfully developed an ultra-slow Bessel optical bullet for fast three-dimensional imaging of deep tissue by stimulated Raman scattering.
This innovative work to"Time-of-flight resolved stimulated Raman scattering microscopy using counter-propagating ultraslow Bessel light bullets generationThe title is published inLight: Science & Applications. National University of SingaporeLin ShulangFirst author of the paper, National University of SingaporeProfessor Wong Chi-waiThe corresponding author of the paper.
The researchers used a pyramid lens and a spatial light modulator to achieve efficient angular dispersion modulation, producing a multi-channel opposite-flying ultra-slow Bessel light bullet with a group velocity of only 0.1c behind the objective lens. By regulating the relative flight time or relative flight speed of the two Bessel light bullets and using only a photodiode detector, fast imaging of stimulated Raman scattering at different depths with time-of-flight resolution is achieved. The scattering self-healing properties of Bessel light bullets transmitted in biological tissues enhance the imaging depth of stimulated Raman scattering. This new method greatly promotes the development and application of nonlinear optical fast three-dimensional biomedical imaging, and provides a new idea for the further study of space-time wave packet.
Stimulated Raman scattering (SRS) microscopy is a spectral imaging technique based on molecular specific vibration, which has excellent chemical specificity and has been widely used in label-free imaging of biological tissues and cells in recent years. However, traditional SRS microscopes use tightly focused Gaussian excitation beams. When these beams pass through turbid media (such as opaque biological tissues), due to the uneven refractive index distribution of the medium, they will cause strong light scattering effects, resulting in beam distortion. This distortion reduces the spatial resolution and light penetration ability of SRS microscope, which limits its application in deep tissue three-dimensional imaging.
The non-diffracting Bessel beam has strong anti-scattering ability and can improve the imaging depth in three-dimensional imaging. However, scanning directly using a Bessel beam as excitation light can only provide SRS projection images of the sample, lacking depth information. In addition, the existing Bessel beam-based SRS three-dimensional imaging method relies on optical beat technology or optical projection tomography technology, which requires the acquisition of hundreds of spatially encoded projection images for post-processing, reducing the three-dimensional imaging speed. And in the process of projection image acquisition, the movement of the sample will cause motion artifacts in the three-dimensional reconstruction, which will affect the imaging quality.
The time-of-flight method of light pulses is a technique for direct measurement of distances in three-dimensional space without post-processing. However, the traditional time-of-flight method is based on measuring the echo time, which is limited by the spatial length of the pulse and the temporal resolution of the detector (Δz≈c×t,t = 10 picoseconds (ps)), and its spatial resolution is on the order of millimeters. In order to improve the resolution of time-of-flight measurement to the order of microns required for microscopic imaging, this work proposes an indirect time-of-flight method: measure the interaction between two light pulses with different group velocities in a nonlinear optical process, and Reduce the group velocity of the light pulse to shorten the pulse space length. In this condition, the time resolution depends on the pulse width of the light (about 100 femtoseconds (fs)). Thus, time-of-flight measurements can be achieved using regular photodetectors (e. g., photodiodes, photomultiplier tubes) without the need to use expensive ultrafast detectors (e. g., streak cameras). At present, in the literature report on pulsed Bessel light, the group velocity generated by ps laser is 0.7c, and the corresponding pulse space length is still on the order of 100 microns, which cannot be used for high-resolution imaging of biological cells and tissues.
In order to break through the bottleneck of existing technology, the research team has developed a new type of stimulated Raman scattering based on time-of-flight resolvable Bessel light bullets (B2-SRS) microscopic imaging technology to achieve rapid three-dimensional chemical imaging of deeper tissues. This work proposes a unique angular dispersion control scheme, using only a pyramid lens and a spatial light modulator to simultaneously convert the pump and Stokes beam pulses into ultra-slow Bessel optical bullets, and two beams of Bessel The group velocity of the optical bullet can be independently controlled in time and space by changing the phase modulation. The more striking feature is that this work produces ultra-slow pump and Stokes Bessel optical bullets that transmit in reverse along the axial direction in biological samples. Its group velocity is only one-tenth of the speed of light, and the space length is also shortened to micron size, which is very suitable for microscope imaging. Therefore, by controlling the depth at which the two Bessel light bullets meet inside the biological sample and manipulating their relative flight time or relative flight speed, a depth-resolvable SRS signal can be quickly obtained without mechanical axial scanning.

Figure 1: Stimulated Raman scattering of time-of-flight resolved Bessel light bullets (B2-SRS) working principle of 3D microscopic imaging
In order to generate an ultra-slow bezier light bullet with fs pulses, the team designed a simple and efficient angular dispersion modulation scheme. The pyramid lens performs wavefront modulation first. The phase pattern displayed on the spatial light modulator is composed of two annular gratings with different grating periods and opposite grating angles. They are used to pump and Stokes beam pulses to produce opposite angular dispersion, so as to realize the forward transmission Stokes Bessel optical bullet (group velocity is 0.1c) and the reverse transmission pump Bessel optical bullet (group velocity is -0.1c). Since both the cone lens and the spatial light modulator are axially symmetric, high quality ultra-slow Bessel light bullets can be produced and applied to high-resolution tissue imaging.

Figure 2: Angular dispersion control device
Teams demonstrated Bessel light bullets for stimulated Raman scattering (B2-SRS) advantages of microscopy in three-dimensional chemical imaging of deep brain tissue. In relatively shallow tissue regions (e. g., z<50 μm),B2-Both SRS and C- SRS can produce SRS signals with high signal-to-noise ratio. However, as the imaging depth increases (e. g., z>100 μm), the SRS signal is only in B2-It is clearly visible in the SRS image, but almost impossible to detect in the C- SRS image. Therefore, compared with conventional SRS imaging, B2-The penetration depth of the SRS technique in brain tissue imaging is more than doubled, demonstrating its remarkable anti-scattering properties in turbid media.

Figure 3:B2-Comparison of SRS and traditional SRS(C-SRS) three-dimensional brain imaging (Raman peak is 2935 cm-1)
Outlook
The present work uses Bessel light bullets for stimulated Raman scattering (B2-SRS) microscopy, which is unique in the measurement of the nonlinear optical interaction process between two optical pulses with different group velocities by generating reverse transmission ultra-slow Bessel photoelasticity. The depth information of the SRS signal generation can be controlled by changing the relative velocity or relative time of flight of the two Bessel photobombs. B based on time of flight2-The spatial resolution of SRS technology is at least three orders of magnitude higher than the millimeter resolution of traditional lidar. This technique overcomes the limitations of traditional SRS microscopy in deep tissue imaging and enables fast, high-resolution three-dimensional chemical imaging under label-free conditions. This method can be widely extended to other nonlinear imaging modes and the field of spatiotemporal light pulse control, which greatly broadens the development of advanced three-dimensional microscopic imaging technology in biomedical systems and other fields.