All Categories >

Product

+
  • 629f5c50-d2ae-42fe-bfa6-3dba9e8a97d1.png

ORIC® Rotary Translation Stage

RIC® Rotary Translation Stage, Piezoelectric Inertial Actuator 360° rotary translation stage with open-loop or closed-loop positioning Piezoelectric inertial drive is ideally suited for setting and maintaining position in applications Maximum speed of 100°/s and a typical step size of 30 µrad (requires PDXC controller) Zero-backlash operation

Detail

Parameters

Technical Data

● Compact stainless steel translation stage with a piezoelectric inertial actuator

● Ideal for OEMs and setup-and-hold applications that require relative positioning and high resolution.

● The central hole can be accessed via a beam or by mounting optomechanical components.

● A variety of different types of translation stages are available (see Table 1.1)

● There are 8–32 (M4 × 0.7) threaded holes on both sides, used for Install the mounting post

● Stacking 20 mm or 50 mm Translation stage, configured as an XY + rotation setup (see Figures 1.3 and 1.4).

● Stacking 4.5 mm vertical translation stage , construct the Z+ rotation configuration

● A piezoelectric inertial controller is required (sold separately)

● The vacuum-compatible version is suitable for pressure environments as low as 10⁻⁶ Torr.

 

  • Due to open-loop design, component variations, and operating conditions, the clockwise and counterclockwise speeds may differ by as much as 50%. Using incorrect software settings to control the stage can further exacerbate this discrepancy. If you are using a KIMx01 controller, be sure to set the stage type to “PD(R)” in the Kinesis software. For applications requiring balanced bidirectional speed, we recommend using a PDXC or PDXC2 controller to independently adjust the forward and reverse drive voltage amplitudes, thereby minimizing speed differences.
  • Use PDXC, PDXC2, and PDXC3 to control at a step frequency of 20 kHz, and use KIM001 or KIM101 to control at a frequency of 2 kHz.
  • Assume a 100 g (0.22 lb) load extends 10 mm from the stage. Larger loads or longer extensions will increase oscillation, potentially leading to stage failure.
  • Long-term operation in the vertical orientation (>3 billion steps) may cause guideway creep, leading to a reduction in travel. To restore the stage’s performance, we recommend reorienting the stage to the horizontal plane after 1 billion vertical steps and performing several back-and-forth movements across the full travel range.
  • Use T5026 Male-to-male SMC adapter and PAA101 A 1.5 m SMC cable can be used to extend the cable. Please note that, due to the cable’s capacitance, the total length of the control cable should not exceed 2.5 m.
  • Compared with the K-Cube controller, the PDXC and PDXC2 offer higher operating frequencies but lower maximum output voltages. They drive the PDR1C(/M) piezo stage at higher speeds, with finer step sizes and reduced drive torque.
  • The PDR1C(/M) translation stage with an SMC connector requires a PDXC2AD D‑sub to SMC conversion cable for use with the PDXC2 or PDXC3 controller.

  • All specifications were measured using the KIM101 K-Cube four‑channel piezoelectric inertial motor controller at a frequency of 2 kHz and a voltage of 85 V, with the stage mounted on a surface having a flatness of ≤20 μm.
  • Due to component variations, changes in orientation, and differing application conditions, a 20% discrepancy may occur.
  • By adjusting the piezoelectric drive voltage and frequency. See details. KIM001 or KIM101 Controller Manual.
  • Specify the frequency in 2 kHz steps.
  • Assume a 100 g (0.22 lb) load extends 15 mm from the stage. Larger loads or longer extensions will increase deflection, potentially leading to stage failure.
  • Driven by the KIM101 controller at frequencies below 2000 Hz and voltages up to 85 V.
  • This service life is valid under normal atmospheric conditions. When the stage is operated in a vacuum, heat can only be dissipated through the stage itself, and wear will be more severe than in an atmospheric environment. Consequently, the stage’s service life will be shortened.
  • Use T5026 SMC male-to-male adapter and PAA101 A 1.5 m SMC cable can be used to extend the cable. Please note that, due to the cable’s capacitance, the total length of the control cable should not exceed 2.5 m.
  • The total length of the included cable is 1.75 m. Please note that, due to the cable’s capacitance, the overall length of the control cable should not exceed 2.5 m.

  • Except where otherwise specified, all specifications apply to PDXC, PDXC2, or PDXC3 controllers (see PDXC Controller for details). Manual , PDXC2 controller Manual or PDXC3 controller Manual ) Measurements were performed. The translation stage was mounted on a surface with flatness ≤ 5 μm.
  • Specified at a drive frequency of 20 kHz and in closed-loop mode.
  • The stage’s velocity is adjusted by varying the voltage amplitude at a constant drive frequency of 20 kHz, whether in open-loop or closed-loop mode, ensuring that no audible noise is generated during operation.
  • Assume a 100 g (0.22 lb) load extends 15 mm from the stage. Larger loads or longer extensions will increase deflection, potentially leading to stage failure.
  • The translation stage is mounted horizontally on the mounting plate in closed-loop mode at a speed of 30 °/s.
  • Please note that, due to the capacitance of the cable, the total length of the control cable should not exceed 4.5 m.
  • The PDXR1(/M) translation stage must be operated using Thorlabs’ PDXC controller firmware version 1.3.1 or later.

 

ORIC® Rotary Translation Stage

Other Products

I want to consult

Submission