Technical Data
The Ocean HR2 spectrometer has high acquisition speed and excellent thermal stability for applications ranging from plasma monitoring to pharmaceutical analysis. The Ocean HR2 is compact and powerful, with integration times of up to 1 μs and wavelength thermal stability of up to 0.06pixels/°C, helping it to ensure a reliable spectral response to environmental changes. The Ocean HR2 covers 190-880 nm with a selectable slit width to help users adjust the luminous flux and optical resolution.
The Ocean HR2 spectrometer is compatible with Ocean Optics light sources, accessories and software, allowing the user to optimize for different applications. The robust design, high thermal stability and excellent absorbance linearity make the Ocean HR2 suitable not only for everyday laboratory use, but also for embedding into OEM equipment and integration into process lines.
- High resolution-Optical resolution less than 1.0 nm (FWHM)
- Fast acquisition speed-Minimum integration time 1 µs
- Excellent thermal stability-Thermal stability 0.06 pixels/°C
Each Ocean HR2 spectrometer is equippedOceanDirect, which is a powerful cross-platform software development kit (SDK) with an application programming interface (API). OceanDirect allows users to optimize spectrometer performance and analyze critical data.
- Model: HR-2XR200-10 spectrometer (including OceanDirect software)
- Wavelength Range: 200nm - 1μm
- Blaze Wavelength: 200 nm
- Optical Resolution: 0.6 nm
- Pixels: 2048
- Entrance slit: 10 µm
HR-2XR200-10 spectrometer
- Model: HR-2XR200-25 spectrometer (including OceanDirect software)
- Wavelength Range: 200nm - 1μm
- Blaze Wavelength: 200 nm
- Optical Resolution: 0.8 nm
- Pixels: 2048
- Entrance slit: 25 µm
HR-2XR200-25 spectrometer
- Model: HR-2XR500-10 spectrometer (including OceanDirect software)
- Wavelength Range: 190nm - 1.1μm
- Blaze Wavelength: 500 nm
- Optical Resolution: 0.9
- Pixels: 2048
- Entrance slit: 10 µm
HR-2XR500-10 spectrometer
- Model: HR-2XR500-25 spectrometer (including OceanDirect software)
- Wavelength Range: 190nm - 1.1μm
- Blaze Wavelength: 500 nm
- Optical Resolution: 1.1
- Pixels: 2048
- Entrance slit: 25 µm
HR-2XR500-25 spectrometer
Spectroscopy:
Wavelength Range:
190nm - 1.1μm
Blaze Wavelength:
200 nm
500 nm
Optical Resolution:
0.6 nm
0.8 nm
0.9
1.1
Integration Time:
1μs-2s
Corrected linearity:
99.8%
Dark Noise:
20 Counts
Dynamic Range:
2.46 E8 (System)
Signal to Noise Ratio:
380:1
Thermal Stability:
0.06 Pixels/°C
Detector:
Pixels:
2048
Entrance slit:
10 µm
25 µm
Electronics:
A/D Resolution:
16 bit
Connectors:
USB Type-C
16 pin Samtec TFM
Inputs/Outputs:
4 GPIO - 2 Output Strobes - Lamp Enable - Power Input - Trigger Input
Trigger Modes:
Single Strobe - Synchronous Continuous Mode - External Rising Edge
Environmental:
Compliance:
EN 61326-1:2013
Electromagnetic Compatibility Directive – 2004/108/EC
EN55011:2009 w/ A1:2010
IEC 60068-2-64 Edition 2.0 2008-04
IEC 60068-2-32 Edition 2.0 2008-05
Humidity:
<85%
Material:
Anodized Aluminum
Storage Temperature:
-30° to 70° C
Physical:
Dimensions:
150 mm (L) x 107 mm (W) x 48 mm (H)
Weight:
930.6g